English
French
German
Italian
Russian
Spanish
Portuguese
Dutch
Greek
Japanese
Korean
Inquiry Cart 0
Home ProductsVRF Air Conditioner

Digital Cooling R410A VRF Air Conditioner Commercial Air Conditioner Units

Send Me The Latest Product Alerts
(No SPAM - We would not sell or share your e-mail address.)

Digital Cooling R410A VRF Air Conditioner Commercial Air Conditioner Units

Good Quality Digital Cooling R410A VRF Air Conditioner Commercial Air Conditioner Units Sales

Large Image :  Digital Cooling R410A VRF Air Conditioner Commercial Air Conditioner Units

Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd

Verified Supplier

China

Business type: Manufacturer, Distributor/Wholesaler, Agent, Importer, Exporter, Seller, Other

Telephone : 86-0769-83660888-8265

Euroklimat Industrial Park, Huangjiang Dongguan Guangdong China 523766

Product Details:

Place of Origin: China
Brand Name: EuroKlimat
Certification: ARI, CE, ISO9001, ISO14001, OHSAS18001, CRAA, CQC
Model Number: EKRV-A

Payment & Shipping Terms:

Minimum Order Quantity: 1 pcs
Price: Negotiation
Packaging Details: Pallet
Delivery Time: 20 working days after received your payment
Payment Terms: L/C, T/T
Supply Ability: 1500pcs per month
Detailed Product Description
Product Name: Digital Multi-connected Central Air Conditioner Refrigerant: R410A
Cooling Capacity(kW): 10.0 KW~141.0 KW Unit Minimum DimensionsL×H×W (mm×mm×mm): 970×355×1050
Range Of Sound Level DB(A): 56~65 Ultra-long Connecting Pipe: Total Pipe Length:1000m
Charging Per Customer: Electricity Fee Can Be Calculated In Real Time Based On Customers' Actual Usage.

 

EKRV Series Friendly Refrigerant Cooling Only Digital Multi-connected Central Air Conditioner

 

 

Parameter

 

Model  

EKRV

040A1

EKRV

050A1

EKRV

060A1

EKRV

050A1

EKRV

060A1

EKRV

070A1

Cooling capacity kW 10 12.5 15 12.5 15 19
Input power Cooling kW 3.3 4.1 4.9 4.1 4.6 5.9
Power supply  

220V~/50Hz

220V~/50Hz 220V~/50Hz 380V/3N~/50Hz 380V/3N~/50Hz

380V/3N~

/50Hz

Rated current Cooling A 15 18.6 22.3 7.9 8.7 12.2
Connector size Liquid pipe mm 9.52 9.52 9.52 9.52 9.52 9.52
Gas pipe mm 15.88 15.88 15.88 15.88 15.88 15.88
Unit weight kg 120 125 129 125 129 135
Noise dB(A) 59 59 60 59 60 61
Refrigerant type   R410A R410A R410A R410A R410A R410A
Dimensions (W x D x H) mm 970x355x1050 970x355x1255 970x355x1050 970x355x1255

 

Model   EKRV080A1 EKRV100A1 EKRV120A1 EKRV140A1
Cooling capacity kW 25 28 33.5 40
Input power Cooling kW 7 7.8 9.5 11.1
Power supply   380V/3N~/50Hz 380V/3N~/50Hz 380V/3N~/50Hz 380V/3N~/50Hz
Rated current Cooling A 14.8 16.4 18.3 21.4
Connector size Liquid pipe mm 9.52 9.52 12.7 12.7
Gas pipe mm 22.2 22.2 22.2 28.6
Unit weight kg 290 300 305 350
Noise dB(A) 56 57 60 60
Refrigerant type   R410A R410A R410A  
Dimensions (W x D x H) mm 990x840x1840 1290x840x1840

 

Model   EKRV160A1 EKRV180A1 EKRV200A1 EKRV220A1 EKRV240A1
Cooling capacity kW 45 50.5 56 61.5 68
Input power Cooling kW 12.9 14.6 15.5 17.3 19.2
Power supply   380V/3N~/50Hz 380V/3N~/50Hz 380V/3N~/50Hz 380V/3N~/50Hz 380V/3N~/50Hz
Rated current Cooling A 24.1 28.7 31.3 34.9 37.3
Connector size Liquid pipe mm 12.7 12.7 15.88 15.88 15.88
Gas pipe mm 28.6 28.6 28.6 28.6 28.6
Equalizer pipe size mm -- -- -- -- --
Unit weight kg 360 370 590 590 600
Noise dB(A) 60 61 61 62 62
Refrigerant type   R410A R410A R410A R410A R410A
Dimensions (W x D x H) mm 1290x840x1840 1990x840x1840

 

Model   EKRV260A1 EKRV280A1 EKRV300A1 EKRV320A1
Cooling capacity kW 73 78.5 85 90
Input power Cooling kW 20.7 22.4 24 25.8
Power supply   380V/3N~/50Hz 380V/3N~/50Hz 380V/3N~/50Hz 380V/3N~/50Hz
Rated current Cooling A 39.7 42.4 46.8 50.3
Connector size Liquid pipe mm 15.88 15.88 15.88 19.05
Gas pipe mm 34.9 34.9 34.9 34.9
Equalizer pipe size mm 9.52 9.52 9.52 9.52
Unit weight kg 655 665 710 720
Noise dB(A) 62 62 62 63
Refrigerant type   R410A R410A R410A R410A
Dimensions (W x D x H) mm 2280x840x1840 2580x840x1840

 

Model   EKRV340 A1 EKRV360 A1 EKRV380 A1 EKRV400 A1 EKRV420 A1
Cooling capacity kW 95.5 101 108 113 118.5
Input power Cooling kW 27.5 29.2 30.3 32.1 33.8
Power supply   380V/3N~/50Hz 380V/3N~/50Hz 380V/3N~/50Hz 380V/3N~/50Hz 380V/3N~/50Hz
Rated current Cooling A 52.8 57.4 58.7 61.5 66
Connector size Liquid pipe mm 19.05 19.05 19.05 19.05 19.05
Gas pipe mm 34.9 34.9 41.3 41.3 41.3
Equalizer pipe size mm 9.52 9.52 9.52 9.52 9.52
Unit weight kg 730 740 950 960 970
Noise dB(A) 63 63 64 64 64
Refrigerant type   R410A R410A R410A R410A R410A
Dimensions (W x D x H) mm 2580x840x1840 3280x840x1840

 

Model   EKRV440 A1 EKRV460 A1 EKRV480 A1 EKRV500 A1
Cooling capacity kW 124 129.5 136 141
Input power Cooling kW 34.7 36.5 38.4 40.2
Power supply   380V/3N~/50Hz 380V/3N~/50Hz 380V/3N~/50Hz 380V/3N~/50Hz
Rated current Cooling A 68.6 72.2 74.7 78.2
Connector size Liquid pipe mm 19.05 19.05 19.05 19.05
Gas pipe mm 41.3 41.3 41.3 41.3
Equalizer pipe size mm 9.52 9.52 9.52 9.52
Unit weight kg 1190 1190 1200 1200
Noise dB(A) 65 65 65 65
Refrigerant type   R410A R410A R410A R410A
Dimensions (W x D x H) mm 3980x840x1840

 

 

Description:

 

Higher Energy Efficiency

ide Capacity Regulation Range and Precise Ambient Temperature Control

By using a PWM valve to control the time ratio of unloading and loading status, the digital scroll compressor can continuously regulate the capacity within a range of 10%–100%, increasing the precision of capacity regulation and the stability of indoor temperature.

Low Energy Consumption

The unit boasts an outstanding IPLV(C) (refrigerating coefficient of performance). The full series of units features an IPLV(C) that is far higher than national standard energy efficiency level 1.

 

More Advanced Technologies

Rapid Start Technologies

EKRV series digital multi-connected central air conditioners can run in full load within a short period, quickly meeting indoor requirements.

 

Supercooling Technologies

Enlarges the condenser of the outdoor unit to implement level-1 supercooling, and then uses an efficient supercooler to implement level-2 supercooling, reaching a total supercooling degree of 19.6°C. Enhances the cooling capability of the unit and improves the efficiency of the unit. Reduces the pressure loss when the refrigerant is circulated in the pipe, rationally allocating the ultra-long accessory pipe and refrigerant.

 

No Electromagnetic Interference

Without a transducer, EKRV series digital multi-connected central air-conditioning units do not generate high-order harmonic and electromagnetic radiation, providing customers with healthy living and working environment.

 

Brushless DC motor (optional)

Fans of outdoor units can be regulated at 32 levels based on load changes, improving efficiency and reducing noise.

The unit can safely run under light load for a long time.

Intelligent Defrosting Technologies;

No Power Consumption Resulting from Power Conversion

 

Wide operation range

EKRV series digital multi-connected central air-conditioning units can generate cooling result in hot weather with a temperature of 54°C.

 

Ultra-long Connecting Pipe

Total pipe length

1000m

Max. equivalent length of a single pipe

220m

Max. actual length of a single pipe

175m

Max. vertical span between outdoor and indoor units

50m

Max. vertical span between indoor units

15m

 

Easy Installation

The system can provide an external static pressure of 50 Pa, ensuring the heat dissipation result of the outdoor unit under the same installation conditions (optional).

A higher external static pressure ensures that the outdoor unit can be flexibly installed at a rooftop, compartment, balcony, or equipment floor, preventing overload of the unit due to poor ventilation

 

More Secure

Dual Backup Operation with Guaranteed Security

Automatic Fault Diagnosis

Technologies for Automatic Identification of Pipe Length

Multiple Measures to Effectively Protect Compressors

Door Card Function (Optional)

Intelligent and Balanced Operation Management

 

Electronic expansion valve

The unit uses an electronic expansion valve with 4000-step capacity regulation to increase the precision of superheat degree control (liquid level control), enhance the operation security, and improve energy saving.

 

More Intelligent

Centralized Monitoring Software

One set of EKRV centralized monitoring software can control up to 2048 indoor units, meeting customers' requirements for large-scale centralized management.

 

Separate Control Charging per Customer

The unit can fairly and rationally divide the electricity quantity based on the model, operation mode, operation time, air supply/ return efficiency, and refrigerant flow of the air conditioning unit to protect the rights and interests of all owners. The unit provides customers with functions such as owner management, price and recharge management, energy saving management.

Separate Control

Centralized Control

 

Models of indoor units are diverse for selection.

Indoor units cover 6 series and 63 capacity types, and total fresh air indoor units are available, fully meeting customer requirements.

 

More Environment-friendly

Full Compliance with RoHS Directive,

Environment-friendly Refrigerant,

Automatic Refrigerant Recovery Technologies,

Automatic Determination of Refrigerant Charge,

Energy Consumption of 5 W in Standby Mode(a Record Low in the Industry)

 

Applications

hotels,entertainment centers, hospitals, restaurants, office buildings, cinemas,

factories, school supermarkets and so on.

 

Competitive Advantage:

EKRV unit using R410A refrigerant meets the energy saving and environmental protection.

Wide operation range. EKRV series digital multi-connected central air-conditioning units can generate cooling result in hot weather with a temperature of 54°C.

Models of indoor units are diverse for selection. Indoor units cover 6 series and 63 capacity types, and total fresh air indoor units are available, fully meeting customer requirements.